Class J Fuse Holders - Gen2 - DFC
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Produktdatenblätter
- DS-Class-J-Fuse-Holders-Gen2-Mersen-EN
pdf - 631.3 KB
Charts
- CHT-Class-J-Fuse Blocks-Gen2-Cross-Reference-Mersen-EN
pdf - 293.1 KB
Produktvorteile
DIN-rail mountable, 600V, 30-100A fuse bases
30A is available with box, screw, and pressure plate terminations; 60A & 100A is available with box only
Fresh new Mersen gray color for fuse base
Dovetail design for interlocking configuration of 2-pole and 3-pole bases
Unique molding around the termination to accommodate hinged cover and for increased safety
Built-in lockout/tagout feature
IP20 finger safe
New clear covers with indicators for safety and visual inspections
Multi-connector wiring options
Anwendungen
Branch circuits
Control panels
Load centers
Lighting, heating, & general loads
Frequenz (Hz) | 50/60 Hz |
Bemessungsstrom | 0 to 100 A |
Sicherungs Klasse | Klasse J |
Kurzschlussstrom-Bewertung (SCCR) | 200 kA |
Entflammbarkeitsbewertung | 94 V-0 |
UL-Kategoriecode | IZLT |
CSA Dateinummer | Class 6225-01, File 032169_0_000 |
Max Betriebstemperatur | 80 °C |
Max. Lagertemp. | 80 °C |
Min. Lagertemp. | -25 °C |
harmonisiertes System | 853890 |
UL Dateinummer | E90426 |
Referenz-Finder
Scroll
Teilenummer | Produkttypen | Beschreibung | Produktgewicht |
---|---|---|---|
FBC60J100 Zum produkt
|
Fuse Block Cover | Gen2 Safety Cover 600V J 100A W/O IND | 0.0181kg |
FBC60J100I Zum produkt
|
Fuse Block Cover | Gen2 Safety Cover 600V J 100A W/IND | 0.0181kg |
FBC60J30 Zum produkt
|
Fuse Block Cover | Sicherungsblock Klasse J 1 Pol | 0.0091kg |
FBC60J30I Zum produkt
|
Fuse Block Cover | Gen2 Safety Cover 600V J 30A W/IND | 0.0091kg |
FBC60J60 Zum produkt
|
Fuse Block Cover | Gen2 Safety Cover 600V J 60A W/O IND | 0.0136kg |
FBC60J60I Zum produkt
|
Fuse Block Cover | Gen2 Safety Cover 600V J 60A W/IND | 0.0136kg |