Class J Fuse Holders - Gen2
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Produktdatenblätter
- DS-Class-J-Fuse-Holders-Gen2-Mersen-EN
pdf - 631.3 KB
Charts
- CHT-Class-J-Fuse Blocks-Gen2-Cross-Reference-Mersen-EN
pdf - 293.1 KB
Compliance
- COM-CE-ROHS-Declaration_Class J_-_Fuse Holders-23-0003
pdf - 176.51 KB
Produktvorteile
DIN-rail mountable, 600V, 30-100A fuse bases
30A is available with box, screw, and pressure plate terminations; 60A & 100A is available with box only
Fresh new Mersen gray color for fuse base
Dovetail design for interlocking configuration of 2-pole and 3-pole bases
Unique molding around the termination to accommodate hinged cover and for increased safety
Built-in lockout/tagout feature
IP20 finger safe
New clear covers with indicators for safety and visual inspections
Multi-connector wiring options
Anwendungen
Branch circuits
Control panels
Load centers
Lighting, heating, & general loads
Frequenz (Hz) | 50/60 Hz |
Bemessungsstrom | 0 to 100 A |
Sicherungs Klasse | Klasse J |
Kurzschlussstrom-Bewertung (SCCR) | 200 kA |
Entflammbarkeitsbewertung | 94 V-0 |
UL-Kategoriecode | IZLT |
CSA Dateinummer | Class 6225, File 032169_0_000 |
Max Betriebstemperatur | 80 °C |
Max. Lagertemp. | 80 °C |
Min. Lagertemp. | -25 °C |
harmonisiertes System | 853690 |
UL Dateinummer | File E52283 |
Referenz-Finder
Scroll
Teilenummer | Bemessungsstrom | Sicherungsgröße | Sicherungstyp / Klasse | Anzahl der Stangen | Anzeigesystem | Produktgewicht |
---|---|---|---|---|---|---|
FB60J100B1 Zum produkt
|
100A | - | Class J | 1-Pole | Nein | 0.2087kg |
FB60J100B2 Zum produkt
|
100A | - | Class J | 2-Pole | Nein | 0.4173kg |
FB60J100B3 Zum produkt
|
100A | - | Class J | 3-Pole | Nein | 0.6305kg |
FB60J30B1 Zum produkt
|
30A | - | Class J | 1-Pole | Nein | 0.0816kg |
FB60J30B2 Zum produkt
|
30A | - | Class J | 2-Pole | Nein | 0.1588kg |
FB60J30B3 Zum produkt
|
30A | - | Class J | 3-Pole | Nein | 0.2404kg |
FB60J30P1 Zum produkt
|
30A | - | Class J | 1-Pole | Nein | 0.0816kg |
FB60J30P2 Zum produkt
|
30A | - | Class J | 2-Pole | Nein | 0.1588kg |
FB60J30P3 Zum produkt
|
30A | - | Class J | 3-Pole | Nein | 0.2404kg |
FB60J30S1 Zum produkt
|
30A | - | Class J | 1-Pole | Nein | 0.0816kg |