MDC10A - DC-Verteilung
With the evolution of DC distribution and new technologies on the horizon, Mersen’s MDC DC Distribution Series is the product line to help customers achieve ultimate protection for today and tomorrow. The product portfolio allows system integrators and OEM manufacturers to select fuses easily for the protection of DC distribution in a variety of applications.
The MDC Series incorporates proven fuse technologies which provide optimal current limitation while achieving maximum performance. The MDC portfolio is designed to easily allow customers to choose fuses where coordination with other DC components is critical, eliminating unnecessary downtime.
With the evolution of DC distribution and new technologies on the horizon, Mersen’s MDC DC Distribution Series is the product line to help customers achieve ultimate protection for today and tomorrow. The product portfolio allows system integrators and OEM manufacturers to select fuses easily for the protection of DC distribution in a variety of applications.
The MDC Series incorporates proven fuse technologies which provide optimal current limitation while achieving maximum performance. The MDC portfolio is designed to easily allow customers to choose fuses where coordination with other DC components is critical, eliminating unnecessary downtime.
Produktdatenblätter
Compliance
- COM-REACH-RE000153-MDC-Mersenpdf - 277.71 KB 
- 23-0014 MDC10A-20230728pdf - 188.06 KB 
Produktvorteile
- Designed for DC applications 
- Low watt losses 
- High cycling performance 
- Low & high current interrupting capability 
- Ultra compact size 
Anwendungen
- DC Distribution 
- DC Cabling and Bus 
- DC Auxiliary Circuits 
- Electrical Energy Storage 
- EV Charging 
- Critical Power 
- UPS Protection 
| Spannungsbereich | 750VAC, 1000VDC | 
| Frequenz (Hz) | 50/60 Hz | 
| Bemessungsstrom | 1 to 30A | 
| Betriebsklasse / Charakteristik | Flinke Auslösung | 
| UL-Kategoriecode | JFHR2 | 
| CSA Dateinummer | Class 1422-01 Guide 049184_0_000 | 
| REACH konform | Ja | 
| Max Betriebstemperatur | 80 °C | 
| Max. Lagertemp. | 80 °C | 
| Min. Lagertemp. | -25 °C | 
| harmonisiertes System | 853610 | 
| UL Dateinummer | File E60314 | 
Referenz-Finder
Scroll
| Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschalt- I2t bei Bemessungsbetriebsspannung | Anzeigesystem | Produktgewicht | 
|---|---|---|---|---|---|
| MDC10A1 Zum produkt | 1A | - | - | Nein | 0.0054kg | 
| MDC10A10 Zum produkt | 10A | - | - | Nein | 0.0054kg | 
| MDC10A10S Zum produkt | 10A | - | - | Nein | 0.0099kg | 
| MDC10A12 Zum produkt | 12A | - | - | Nein | 0.0054kg | 
| MDC10A12S Zum produkt | 12A | - | - | Nein | 0.0099kg | 
| MDC10A15 Zum produkt | 15A | - | - | Nein | 0.0054kg | 
| MDC10A15S Zum produkt | 15A | - | - | Nein | 0.0099kg | 
| MDC10A1S Zum produkt | 1A | - | - | Nein | 0.0099kg | 
| MDC10A2 Zum produkt | 2A | - | - | Nein | 0.0054kg | 
| MDC10A20 Zum produkt | 20A | - | - | Nein | 0.0054kg | 