MDC08B - DC Distribution
Mersen’s MDC battery module fuse is designed and tested for the protection of battery modules. The MDC08B series provides back-up protection to the battery module during shipping, transportation, and handling of the module.
The MDC08B Series incorporates proven fuse technologies which provides optimal current limitation while achieving maximum performance. The battery module fuse is designed to provide back-up protection while maintaining a slow melting time. It is important for a battery module fuse to have a slower melting time to ensure coordination with upstream fuses can be achieved. This allows battery module manufactures the ease of mind that the battery is protected during shipping, handling, and transportation and once installed within a system, that the traditional fast-acting upstream fuses will coordinate with the battery.
Mersen’s MDC battery module fuse is designed and tested for the protection of battery modules. The MDC08B series provides back-up protection to the battery module during shipping, transportation, and handling of the module.
The MDC08B Series incorporates proven fuse technologies which provides optimal current limitation while achieving maximum performance. The battery module fuse is designed to provide back-up protection while maintaining a slow melting time. It is important for a battery module fuse to have a slower melting time to ensure coordination with upstream fuses can be achieved. This allows battery module manufactures the ease of mind that the battery is protected during shipping, handling, and transportation and once installed within a system, that the traditional fast-acting upstream fuses will coordinate with the battery.
Produktdatenblätter
- DS-MDC08B-DC-Distribution-Fuse-Mersen-ENpdf - 1.63 MB 
Produktvorteile
- Designed for DC applications 
- Low watt losses 
- High cycling performance 
- Low & high current interrupting capability 
- Ultra compact size 
Anwendungen
- Battery modules protection 
- Stationary DC systems 
- Battery systems 
| Spannungsbereich | 80VAC, 80VDC | 
| Bemessungsstrom | 35 to 750A | 
| Betriebsklasse / Charakteristik | Flinke Auslösung | 
| UL-Kategoriecode | JFHR2 | 
| Max Betriebstemperatur | 80 °C | 
| Max. Lagertemp. | 80 °C | 
| Min. Lagertemp. | -25 °C | 
| harmonisiertes System | 853610 | 
| UL Dateinummer | File E60314 | 
Referenz-Finder
Scroll
| Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschalt- I2t bei Bemessungsbetriebsspannung | Anzeigesystem | Produktgewicht | 
|---|---|---|---|---|---|
| MDC08B325B Zum produkt | 325A | - | - | Nein | 0.0181kg | 
| MDC08B350B Zum produkt | 350A | - | - | Nein | 0.0181kg | 
| MDC08B35B Zum produkt | 35A | - | - | Nein | 0.0181kg | 
| MDC08B400B Zum produkt | 400A | - | - | Nein | 0.0181kg | 
| MDC08B40B Zum produkt | 40A | - | - | Nein | 0.0181kg | 
| MDC08B500B Zum produkt | 500A | - | - | Nein | 0.0181kg | 
| MDC08B50B Zum produkt | 50A | - | - | Nein | 0.0181kg | 
| MDC08B60B Zum produkt | 60A | - | - | Nein | 0.0181kg | 
| MDC08B80B Zum produkt | 80A | - | - | Nein | 0.0181kg | 