HelioProtection® HP20Pxx 2000VDC Solar Fuses 22x85mm
Mersen’s range of 2000VDC photovoltaic (PV) fuse series is designed specifically to meet higher amperage demands of today’s PV circuits. Mersen’s 22x85mm form factor is designed to handle the harsh cyclical loads and thermal conditions of our customers’ highest amperage applications. These 2000VDC rated fuses are designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, which allows for safe circuit interruption under typical low fault current conditions. In addition to the standard ferrule terminal, fuses are also available with Crimp Cap terminals for in-line fuse applications. The unique wire crimp terminal (CC option) permits solderless wire-to-fuse connection for overmold encapsulation of fuse and wiring. Protect your off-grid or grid tied PV system from unexpected line faults using Mersen’s HelioProtection® fuse line.
Mersen’s range of 2000VDC photovoltaic (PV) fuse series is designed specifically to meet higher amperage demands of today’s PV circuits. Mersen’s 22x85mm form factor is designed to handle the harsh cyclical loads and thermal conditions of our customers’ highest amperage applications. These 2000VDC rated fuses are designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, which allows for safe circuit interruption under typical low fault current conditions. In addition to the standard ferrule terminal, fuses are also available with Crimp Cap terminals for in-line fuse applications. The unique wire crimp terminal (CC option) permits solderless wire-to-fuse connection for overmold encapsulation of fuse and wiring. Protect your off-grid or grid tied PV system from unexpected line faults using Mersen’s HelioProtection® fuse line.
Produktdatenblätter
- DS-HP20P-HelioProtection-Photovoltaic Fuses-Mersen-EN
pdf - 312.58 KB
Compliance
- COM-CE-ROHS-Declaration_Class_Type_PV-23-0002
pdf - 173.24 KB
Produktvorteile
20A to 60A for higher amperage applications
Low fault current interrupting capability
Durable construction for enhanced system longevity
Temperature and load cycling capability
Certified to global standards
Recommended fuse holders: HP15FHP80W, HP15FHP80B
Anwendungen
All photovoltaic applications
PV string/array level protection
Combiner box applications
In-line PV module protection
Inverters
Battery charge controllers
Bemessungsstrom | 20 to 60A |
Sicherungs Betriebsklasse | PV |
Betriebsklasse / Charakteristik | gPV |
UL-Kategoriecode | JFGA |
CSA Dateinummer | Class 1422-03 Guide 012636_0_000 |
Max Betriebstemperatur | 80 °C |
Min. Betriebstemperatur | -30 °C |
Max. Lagertemp. | 80 °C |
Min. Lagertemp. | -30 °C |
harmonisiertes System | 853510 |
UL Dateinummer | E333668 |
Referenz-Finder
Scroll
Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschalt- I2t bei Bemessungsbetriebsspannung | Anzeigesystem | Produktgewicht |
---|---|---|---|---|---|
HP20P40 Zum produkt
|
40A | - | - | Nein | 0.068kg |
HP20P40CC Zum produkt
|
40A | - | - | Nein | 0.1134kg |
HP20P45 Zum produkt
|
45A | - | - | Nein | 0.068kg |
HP20P45CC Zum produkt
|
45A | - | - | Nein | 0.1134kg |
HP20P50 Zum produkt
|
50A | - | - | Nein | 0.068kg |
HP20P50CC Zum produkt
|
50A | - | - | Nein | 0.1134kg |
HP20P55 Zum produkt
|
55A | - | - | Nein | 0.068kg |
HP20P55CC Zum produkt
|
55A | - | - | Nein | 0.1134kg |
HP20P60 Zum produkt
|
60A | - | - | Nein | 0.068kg |
HP20P60CC Zum produkt
|
60A | - | - | Nein | 0.1134kg |