HelioProtection® HP15Pxx 1500VDC Solar Fuses 20x65mm
Mersen’s range of 1500VDC photovoltaic (PV) fuse series is designed specifically to meet higher amperage demands of today’s PV circuits. Mersen’s 20x65mm form factor is designed to handle the harsh cyclical loads and thermal conditions of our customers’ highest amperage applications. These 1500VDC rated fuses are designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, which allows for safe circuit interruption under typical low fault current conditions. In addition to the standard ferrule terminal, fuses are also available with Crimp Cap terminals for in-line fuse applications. The unique wire crimp terminal (CC option) permits solderless wire-to-fuse connection for overmold encapsulation of fuse and wiring. Protect your off-grid or grid tied PV system from unexpected line faults using Mersen’s HelioProtection® fuse line.
Mersen’s range of 1500VDC photovoltaic (PV) fuse series is designed specifically to meet higher amperage demands of today’s PV circuits. Mersen’s 20x65mm form factor is designed to handle the harsh cyclical loads and thermal conditions of our customers’ highest amperage applications. These 1500VDC rated fuses are designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, which allows for safe circuit interruption under typical low fault current conditions. In addition to the standard ferrule terminal, fuses are also available with Crimp Cap terminals for in-line fuse applications. The unique wire crimp terminal (CC option) permits solderless wire-to-fuse connection for overmold encapsulation of fuse and wiring. Protect your off-grid or grid tied PV system from unexpected line faults using Mersen’s HelioProtection® fuse line.
Produktdatenblätter
- DS-HP15P-Fuse-Mersen-EN
pdf - 328.83 KB
Compliance
- COM-CE-ROHS-Declaration_Class_Type_PV-23-0002
pdf - 173.24 KB
Produktvorteile
10A to 65A for higher amperage applications
Low fault current interrupting capability
Durable construction for enhanced system longevity
Temperature and load cycling capability
Certified to global standards
Recommended fuse holders: HP15FHP80W, HP15FHP80B
Anwendungen
All photovoltaic applications
PV string/array level protection
Combiner box applications
In-line PV module protection
Inverters
Battery charge controllers
Bemessungsstrom | 10 to 65A |
Sicherungs Klasse | PV |
Betriebsklasse / Charakteristik | gPV |
UL-Kategoriecode | JFGA |
CSA Dateinummer | Class 1422-03 Guide 012636_0_000 |
CE-Konformität | Ja |
Max Betriebstemperatur | 80 °C |
Min. Betriebstemperatur | -30 °C |
Max. Lagertemp. | 80 °C |
Min. Lagertemp. | -30 °C |
harmonisiertes System | 853510 |
UL Dateinummer | E333668 |
Referenz-Finder
Scroll
Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschaltintegral I2t bei Nennspannung | Anzeigesystem | Produktgewicht |
---|---|---|---|---|---|
HP15P10 Zum produkt
|
10A | - | - | Nein | 0.0499kg |
HP15P10CC Zum produkt
|
10A | - | - | Nein | 0.0907kg |
HP15P12 Zum produkt
|
12A | - | - | Nein | 0.0499kg |
HP15P12CC Zum produkt
|
12A | - | - | Nein | 0.0907kg |
HP15P15 Zum produkt
|
15A | - | - | Nein | 0.0499kg |
HP15P15CC Zum produkt
|
15A | - | - | Nein | 0.0907kg |
HP15P20 Zum produkt
|
20A | - | - | Nein | 0.0499kg |
HP15P20CC Zum produkt
|
20A | - | - | Nein | 0.0907kg |
HP15P25 Zum produkt
|
25A | - | - | Nein | 0.0499kg |
HP15P25CC Zum produkt
|
25A | - | - | Nein | 0.0907kg |