Zurück
Wo zu kaufen Kontakt
PHP-BSFPgG-MSL

BS88 Feeder pillar fuses gG 415 VAC

Technische Normen
ASTA 20
EN 60269-2
BS88-2

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

Produktvorteile

  • Better coordination

  • Immediate isolation

  • Ensures fire safety

Anwendungen

  • Feeder pillar for street lighting

  • Electricity Supply Industries in distribution pillars

  • Open type substation boards

  • Heavy duty service cut-outs

  • Underground disconnecting boxes

Produktspezifikationen
Spannungsbereich 415 VAC
Bemessungsstrom 20-630A
Betriebsklasse / Charakteristik gG
CE-Konformität Ja

Referenz-Finder

Teilenummer Bemessungsstrom Sicherungsgröße Ausschalt- I2t bei Bemessungsbetriebsspannung Anzeigesystem Produktgewicht
P1003894 - BJU42V080PA Zum produkt
80A 110x36 21000A²s Nein 0.185kg
Q1003895 - BJU42V100PA Zum produkt
100A 110x36 37000A²s Nein 0.185kg
R1003896 - BJU42V125PA Zum produkt
125A 110x36 74700A²s Nein 0.185kg
S1003897 - BJU42V160PA Zum produkt
160A 110x36 168000A²s Nein 0.185kg
V1003899 - BJU42V020SA Zum produkt
20A 130x36 1125A²s Nein 0.281kg
V1003922 - BJU42V200SA Zum produkt
200A 130x36 256500A²s Nein 0.281kg
W1003900 - BJU42V025SA Zum produkt
25A 130x36 1890A²s Nein 0.281kg
W1003923 - BJU42V250PB Zum produkt
250A 110x42 270000A²s Nein 0.244kg
X1003901 - BJU42V032SA Zum produkt
32A 130x36 3000A²s Nein 0.281kg
Y1003902 - BJU42V040SA Zum produkt
40A 130x36 5850A²s Nein 0.281kg