BS88 Feeder pillar fuses gG 415 VAC
The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.
The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.
The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.
The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.
Produktdatenblätter
- DS-Feeder-Pillar-Fuse-gG-415-VAC-EN
pdf - 386.48 KB
Compliance
- COM-REACH-declaration-IN0001-IEC Low Voltage Fuses
pdf - 234.85 KB
- COM-ROHS-declaration-IN0001-IEC Low Voltage Fuses
pdf - 248.35 KB
Produktvorteile
Better coordination
Immediate isolation
Ensures fire safety
Anwendungen
Feeder pillar for street lighting
Electricity Supply Industries in distribution pillars
Open type substation boards
Heavy duty service cut-outs
Underground disconnecting boxes
Spannungsbereich | 415 VAC |
Bemessungsstrom | 20-630A |
Betriebsklasse / Charakteristik | gG |
CE-Konformität | Ja |
Referenz-Finder
Scroll
Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschalt- I2t bei Bemessungsbetriebsspannung | Anzeigesystem | Produktgewicht |
---|---|---|---|---|---|
H1003888 - BJU42V020PA Zum produkt
|
20A | 110x36 | 1125A²s | Nein | 0.185kg |
H1003911 - BJU42V160SA Zum produkt
|
160A | 130x36 | 168000A²s | Nein | 0.281kg |
H1003934 - BJU42V400SB Zum produkt
|
400A | 130x42 | 720000A²s | Nein | 0.316kg |
H1003957 - BJU42V630SD Zum produkt
|
630A | 130x74 | 3800000A²s | Nein | 0.706kg |
J1003889 - BJU42V025PA Zum produkt
|
25A | 110x36 | 1890A²s | Nein | 0.185kg |
J1003935 - BJU42V450SC Zum produkt
|
450A | 130x50 | 945000A²s | Nein | 0.398kg |
K1003890 - BJU42V032PA Zum produkt
|
32A | 110x36 | 3000A²s | Nein | 0.185kg |
L1003891 - BJU42V040PA Zum produkt
|
40A | 110x36 | 5850A²s | Nein | 0.185kg |
M1003892 - BJU42V050PA Zum produkt
|
50A | 110x36 | 11700A²s | Nein | 0.185kg |
N1003893 - BJU42V063PA Zum produkt
|
- | 110x36 | 18000A²s | Nein | 0.185kg |