BS88 Feeder pillar fuses gG 415 VAC

Technische Normen
ASTA 20
EN 60269-2
BS88-2

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

Produktvorteile

  • Better coordination

  • Immediate isolation

  • Ensures fire safety

Anwendungen

  • Feeder pillar for street lighting

  • Electricity Supply Industries in distribution pillars

  • Open type substation boards

  • Heavy duty service cut-outs

  • Underground disconnecting boxes

Produktspezifikationen
Spannungsbereich 415 VAC
Bemessungsstrom 20-630A
Betriebsklasse / Charakteristik gG
CE-Konformität Ja

Referenz-Finder

Teilenummer Bemessungsstrom Sicherungsgröße Ausschalt- I2t bei Bemessungsbetriebsspannung Anzeigesystem Produktgewicht
H1003888 - BJU42V020PA Zum produkt
20A 110x36 1125A²s Nein 0.185kg
H1003911 - BJU42V160SA Zum produkt
160A 130x36 168000A²s Nein 0.281kg
H1003934 - BJU42V400SB Zum produkt
400A 130x42 720000A²s Nein 0.316kg
H1003957 - BJU42V630SD Zum produkt
630A 130x74 3800000A²s Nein 0.706kg
J1003889 - BJU42V025PA Zum produkt
25A 110x36 1890A²s Nein 0.185kg
J1003935 - BJU42V450SC Zum produkt
450A 130x50 945000A²s Nein 0.398kg
K1003890 - BJU42V032PA Zum produkt
32A 110x36 3000A²s Nein 0.185kg
L1003891 - BJU42V040PA Zum produkt
40A 110x36 5850A²s Nein 0.185kg
M1003892 - BJU42V050PA Zum produkt
50A 110x36 11700A²s Nein 0.185kg
N1003893 - BJU42V063PA Zum produkt
- 110x36 18000A²s Nein 0.185kg