MEV50A500-45G
EVpack-Sicherung 500VDC UL 500VDC IEC 500A Größe 45G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack-Sicherung 500VDC UL 500VDC IEC 500A Größe 45G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Datasheets
Drawings
pdf - 177.14 KB
Compliances
pdf - 157.17 KB
pdf - 157.1 KB
| Teilenummer | MEV50A500-45G | 
| Beschreibung | EVpack-Sicherung 500VDC UL 500VDC IEC 500A Größe 45G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt | 
| EAN / UPC-Code | 6972238870370 | 
| Bemessungsbetriebsspannung DC UL | 500 V | 
| Bemessungsbetriebsspannung DC IEC | 500 V | 
| Bemessungsstrom | 500 A | 
| RoHS-konform | Ja | 
| Wechselstrom oder Gleichstrom | DC | 
| Betriebsklasse / Charakteristik | aR | 
| Baugröße | 45G | 
| Montageart | Geschraubt | 
| Schmelz- I2t | 51210 A²s | 
| Max. Abschaltzeit MBC | 1 s | 
| Max. Nenn-Schaltvermögen DC | 30 kA @ 500 V, L/R ≤ 2.5ms | 
| DC Min. Schaltvermögen (MBC) | 2000 A @ 500 VDC, ≤ 2.5 ms | 
| DC Gesamt-Ausschaltintegral I2t | 400000 A²s | 
| Material der Kontakte | Kupfer mit Zinnbeschichtung | 
| Verbindung / Anschluss Typ | Geschraubt | 
| Produktdurchmesser | 45 mm | 
| Produktlänge | 103 mm | 
| Verpackungsmenge | 4 EA | 
| Verpackungsgewicht | 0.96 kg | 
| Verpackungsbreite | 288 mm | 
| Verpackungslänge | 176 mm | 
| Verpackungshöhe | 107 mm | 
| Produktgruppe | EV and Battery Protection Fuses | 
| Material des (Sicherungs-) Körpers | GMG | 
| Produktgewicht | 0.24 kg | 
| Leistungsdissipation bei Zwischenstromwert | 14.4 W @ 0.5 In |