MEV50A100-20G
EVpack-Sicherung 500VDC UL 500VDC IEC 100A Größe 20G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack-Sicherung 500VDC UL 500VDC IEC 100A Größe 20G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Datasheets
Compliances
pdf - 157.17 KB
pdf - 194.54 KB
pdf - 157.1 KB
Teilenummer | MEV50A100-20G |
Beschreibung | EVpack-Sicherung 500VDC UL 500VDC IEC 100A Größe 20G Max. Ausschaltvermögen DC: 30 kA @ 500 V, L/R ≤ 2.5 ms geschraubt |
EAN / UPC-Code | 6972238870158 |
Nennspannung DC UL | 500 V |
Nennspannung DC IEC | 500 V |
Bemessungsstrom | 100 A |
RoHS-konform | Ja |
Wechselstrom oder Gleichstrom | DC |
Betriebsklasse / Charakteristik | aR |
Sicherungsgröße | 20G |
Montage | Geschraubt |
Schmelzen I2t | 910 A²s |
Max. Abschaltzeit MBC | 33 s |
Max. Nenn-Schaltvermögen DC | 30 kA @ 500 V, L/R ≤ 2.5ms |
DC Min. Schaltvermögen (MBC) | 200 A @ 500 VDC, ≤ 2.5 ms |
DC Gesamt-Ausschaltintegral I2t | 7800 A²s |
Material der Kontakte | Kupfer mit Zinnbeschichtung |
Verbindung / Anschluss Type | Geschraubt |
Produktdurchmesser | 20 mm |
Produktlänge | 81 mm |
Packmenge verkaufen | 30 EA |
Packgewicht verkaufen | 1.3472 kg |
Packbreite verkaufen | 265 mm |
Packlänge verkaufen | 153 mm |
Packhöhe verkaufen | 84 mm |
Produktgruppe | EV and Battery Protection Fuses |
Material des (Sicherungs-) Körpers | GMG |
Produktgewicht | 0.041 kg |
Leistungsdissipation bei Zwischenstromwert | 3.6 W @ 0.5 In |