MEV100A100-4
EVpack-Sicherung 1000VDC UL 100A Max. Ausschaltvermögen DC: 20 kA @ 1000 V L/R ≤ 1 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
EVpack-Sicherung 1000VDC UL 100A Max. Ausschaltvermögen DC: 20 kA @ 1000 V L/R ≤ 1 ms geschraubt
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
Datasheets
pdf - 763.17 KB
Compliances
pdf - 280.24 KB
pdf - 215.15 KB
Teilenummer | MEV100A100-4 |
Beschreibung | EVpack-Sicherung 1000VDC UL 100A Max. Ausschaltvermögen DC: 20 kA @ 1000 V L/R ≤ 1 ms geschraubt |
EAN / UPC-Code | 782001481438 |
Nennspannung DC UL | 1000 V |
Bemessungsstrom | 100 A |
RoHS-konform | Ja |
Wechselstrom oder Gleichstrom | DC |
Montage | Geschraubt |
Mindestunterbrechungsrate (MBC) | 1920 A |
Max. Nenn-Schaltvermögen DC | 20 kA @ 1000 V, L/R ≤ 1 ms |
Material der Kontakte | Messing mit Zinnbeschichtung |
Verbindung / Anschluss Type | Geschraubt |
Produktdurchmesser | 25.4 mm |
Produktlänge | 111 mm |
Packmenge verkaufen | 5 EA |
Packgewicht verkaufen | 0.585 kg |
Packbreite verkaufen | 150 mm |
Packlänge verkaufen | 210 mm |
Packhöhe verkaufen | 40 mm |
Produktgruppe | EV and Battery Protection Fuses |
Produktgewicht | 0.117 kg |
Leistungsdissipation bei Zwischenstromwert | 4.3 W @ 0.5 In |