A6D-R - Class RK1 - Time-Delay
Amp-Trap 2000® time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Amp-Trap 2000® time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Produktdatenblätter
- DS-A2D-R-A6D-R-Class-RK1-Time-Delay-Mersen
pdf - 244.12 KB
Compliance
- COM-REACH-RE000039-A6D-R-Mersen
pdf - 206.93 KB
- COM-REACH-RE000039-A6D-R-Mersen
pdf - 206.93 KB
- COM-RoHS-RS000039-A6D-R-Mersen
pdf - 142.04 KB
Produktvorteile
Non-indicating or Solid state SmartSpot visual blown fuse indicator
Time-delay for motor starting and transformer inrush currents without nuisance opening
600VAC & 600VDC dual rated
300kA interrupting rating - self-certified, UL witnessed tests
Extremely current-limiting for low peak let-thru current
Recommended for Arc Flash energy reduction
Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”
Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
High-visibility orange label gives instant brand recognition
Reduced inventory by taking the place of class RK5, K, and H fuses
Metal-embossed date and catalog number for easier traceability and lasting identification
Fiberglass body provides dimensional stability in harsh industrial settings
Anwendungen
Motors
Safety switches
Transformers
Branch circuit protection
Disconnects
Control panels
All general-purpose circuits
Frequenz (Hz) | 50/60 Hz |
Bemessungsstrom | 1/10 to 600 A |
Sicherungs Klasse | Klasse RK1 |
Betriebsklasse / Charakteristik | Time Delay |
UL-Kategoriecode | JDDZ |
CSA Dateinummer | Class 1422-02 Guide 012636_0 |
REACH konform | Ja |
Max Betriebstemperatur | 80 °C |
Max. Lagertemp. | 80 °C |
Min. Lagertemp. | -25 °C |
harmonisiertes System | 853610 |
UL Dateinummer | File E2137 |
Referenz-Finder
Scroll
Teilenummer | Bemessungsstrom | Sicherungsgröße | Ausschaltintegral I2t bei Nennspannung | Anzeigesystem | Produktgewicht |
---|---|---|---|---|---|
A6D1-1/4R Zum produkt
|
1.25A | - | - | Nein | 0.0662kg |
A6D1-1/8R Zum produkt
|
1.125A | - | - | Nein | 0.0662kg |
A6D1-4/10R Zum produkt
|
1.4A | - | - | Nein | 0.0662kg |
A6D1-6/10R Zum produkt
|
1.6A | - | - | Nein | 0.0662kg |
A6D1-8/10R Zum produkt
|
1.8A | - | - | Nein | 0.0662kg |
A6D1/10R Zum produkt
|
0.1A | - | - | Nein | 0.0662kg |
A6D1/2R Zum produkt
|
0.5A | - | - | Nein | 0.0662kg |
A6D100R Zum produkt
|
100A | - | - | Ja | 0.2803kg |
A6D100RN Zum produkt
|
100A | - | - | Nein | 0.2803kg |
A6D10R Zum produkt
|
10A | - | - | Ja | 0.0662kg |